1000 Groove, UV Holographic, 12.5 X 25 mm, 6 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1000HUVQEAC
Optical Coating
Aluminum
Grooves Per mm
1000
Blaze
UV
Groove Angle
Holographic UV
Dispersion @ 250 nm (nm/mr)
0.99
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
6 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
1000 Groove, UV Holographic, 12.5 X 25 mm, 9.5 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1000HUVQGAC
Optical Coating
Aluminum
Grooves Per mm
1000
Blaze
UV
Groove Angle
Holographic UV
Dispersion @ 250 nm (nm/mr)
0.99
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
1200 Groove, UV Holographic, 12.5 X 25 mm, 6 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1200HUVQEAC
Optical Coating
Aluminum
Grooves Per mm
1200
Blaze
UV
Groove Angle
Holographic UV
Dispersion @ 250 nm (nm/mr)
0.82
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
6 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
1200 Groove, UV Holographic, 12.5 X 25 mm, 9.5 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1200HUVQGAC
Optical Coating
Aluminum
Grooves Per mm
1200
Blaze
UV
Groove Angle
Holographic UV
Dispersion @ 250 nm (nm/mr)
0.82
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
1200 Groove, VIS Holographic, 12.5 X 25 mm, 6 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1200HVISQEAC
Optical Coating
Aluminum
Grooves Per mm
1200
Blaze
VIS
Groove Angle
Holographic VIS
Dispersion @ 500 nm (nm/mr)
0.79
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
6 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
1200 Groove, VIS Holographic, 12.5 X 25 mm, 9.5 mm Thick, CW Type Diffraction Grating
Holographic Diffraction Grating Specifications | G1200HVISQGAC
Optical Coating
Aluminum
Grooves Per mm
1200
Blaze
VIS
Groove Angle
Holographic VIS
Dispersion @ 500 nm (nm/mr)
0.79
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
Optometrics
Holographic Diffraction Gratings with Damage Threshold: Pulsed 3.5 J/cm², 200 nano sec. pulse and Size (mm) 12.5 X 25 mm

High-Quality Holographic Diffraction Gratings
These replicated holographic diffraction gratings are produced on soda lime glass substrates from high quality holographic master gratings and are intended for use in spectrometers and monochromators where cost and low stray light are of primary concern. They exhibit a flatter response due to their sinusoidal groove profile.
↓ Scroll down to view product inventory ↓
Available with either standard or CW-type construction for higher damage threshold performance, holographic diffraction gratings can also be produced on substrates with a lower coefficient of thermal expansion for better stability. No damage threshold minimums apply to diffraction gratings with an overcoat.
Pulsed 350 milli-joules/ cm2 @ 200 n sec.
CW 40 watts/cm2
Pulsed 3.5 joules/ cm2 @ 200 n sec.
CW 250 watts/cm2
For continuous high power applications.
Optometrics develops hybrid grating and optical filter for holographic weapons sight.