300 Groove, ML-501, 12.5 X 25 mm, 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR2.8QGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
2.8μ
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-501, 25 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR2.8GGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
2.8μ
Substrate
Pyrex
Size (mm)
25 mm Sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-501, 25 X 50 mm, 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR2.8TGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
2.8μ
Substrate
Pyrex
Size (mm)
25 X 50 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-501, 30 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR2.8JGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
2.8μ
Substrate
Pyrex
Size (mm)
30 mm Sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-501, 50 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR2.8MGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
2.8μ
Substrate
Pyrex
Size (mm)
50 mm sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-601, 12.5 X 25 mm, 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR3.5QGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
3.5μ
Substrate
Pyrex
Size (mm)
12.5 X 25 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-601, 25 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR3.5GGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
3.5μ
Substrate
Pyrex
Size (mm)
25 mm Sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-601, 25 X 50 mm, 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR3.5TGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
3.5μ
Substrate
Pyrex
Size (mm)
25 X 50 mm
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Grooves Parallel
Short
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-601, 30 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR3.5JGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
3.5μ
Substrate
Pyrex
Size (mm)
30 mm Sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
-
300 Groove, ML-601, 50 mm Sq., 9.5 mm Thick, Replica Diffraction Grating
Molecular Laser Tuning Diffraction Gratings Specifications | G300MR3.5MGAC
Optical Coating
Aluminum
Grooves Per mm
300
Optimum Laser Wavelength
3.5μ
Substrate
Pyrex
Size (mm)
50 mm sq.
Size Tolerance
±0.5 mm
Thickness
9.5 mm
Thickness Tolerance
±0.5 mm
Scratch/Dig
60/40
Clear Aperture
90%
Edge Angle
90° ±0.50°
Perpendicularity
90° ±0.50°
Operating Temperature Range
-50° C to +200° C
Damage Threshold: Pulsed
3.5 J/cm², 200 nano sec. pulse
Damage Threshold: CW laser
250 watts/cm²
Optometrics
Infrared Diffraction Gratings with Optimum Laser Wavelength 3.5μ or 2.8μ
Infrared Diffraction Gratings
These are original rulings or replicas that are typically used for tuning high and low power infrared lasers and wavelength scanning and selection in broadband infrared spectroscopy applications. For high power applications, these same gratings, as well as custom optimized designs, may be supplied as original rulings ruled directly into the metal substrate surface. Please contact Optometrics for custom infrared diffraction gratings.
Original Ruled Diffraction Gratings
Optometrics manufactures these gratings as original gratings ruled directly deposited on a Kanigen®* coated copper substrate with aluminum coating. This gives the original gratings an inherently higher damage threshold than their replicated counterparts which are produced on a Pyrex® substrate. Contact Optometrics to order custom ruled diffraction grating or call +1-978-772-1700.